Need any help?
  • Medical Outlet
  • Medical Outlet
Manual Power Source Stainless Steel 47mm Joint Replacement Prosthesis – Bipolar Prosthesis RG (Cemented) in Pakistan to Pinterest (opens in a new window)

Manual Power Source Stainless Steel 47mm Joint Replacement Prosthesis – Bipolar Prosthesis RG (Cemented) in Pakistan

389,999.00

Manual Power Source Stainless Steel 47mm Joint Replacement Prosthesis – Bipolar Prosthesis RG (Cemented) in Pakistan Medical Outlet offers the 47mm Bipolar Prosthesis RG (Cemented), a stainless steel hip joint replacement implant designed for cemented fixation procedures. Because hip joint replacement surgery requires precise sizing and reliable materials, this bipolar prosthesis gives orthopedic surgeons a …

Add to Wishlist
Add to Wishlist

Manual Power Source Stainless Steel 47mm Joint Replacement Prosthesis – Bipolar Prosthesis RG (Cemented) in Pakistan

Medical Outlet offers the 47mm Bipolar Prosthesis RG (Cemented), a stainless steel hip joint replacement implant designed for cemented fixation procedures. Because hip joint replacement surgery requires precise sizing and reliable materials, this bipolar prosthesis gives orthopedic surgeons a dependable component for joint reconstruction. As a result, it suits hospitals and orthopedic surgical departments performing hip arthroplasty procedures across Pakistan.

This prosthesis works within a bipolar hip replacement system. So, the 47mm Bipolar Prosthesis RG focuses on three things: joint mobility restoration, secure cemented fixation, and durable stainless steel construction. Therefore, it suits surgical teams treating hip fractures, degenerative joint conditions, or cases requiring joint replacement.

How the Bipolar Prosthesis RG (Cemented) Works

This prosthesis replaces the femoral head with a bipolar head assembly, which allows movement at two articulating surfaces — between the femoral stem and the inner bearing, and between the outer shell and the natural acetabulum. Thereby, it helps distribute mechanical stress across the joint during movement. Because the implant uses cemented fixation, bone cement secures the prosthetic stem within the femoral canal, which, in turn, provides immediate mechanical stability after implantation.

Furthermore, the stainless steel construction gives the implant the strength needed to withstand ongoing joint loading. This, in turn, supports its role in long-term joint function following surgery.

Key Features

47mm Head SizeBecause precise sizing matters in hip reconstruction, this dimension supports proper anatomical fit during implantation.

Bipolar DesignConsequently, the dual-articulation structure may help distribute joint stress across two movement surfaces.

Cemented FixationSince bone cement secures the implant to the femoral canal, this approach supports immediate post-operative stability.

Stainless Steel ConstructionAs a result, the implant offers durability suited to ongoing mechanical loading within the joint.

Manual Power SourceOverall, this refers to the manual surgical instrumentation used during implantation rather than any powered mechanism within the prosthesis itself.

RG Series DesignBecause it belongs to the RG product line, it follows a standardized design specification for bipolar hip components.

Technical Specifications

(Please confirm every field against your supplier’s official documentation before publishing)

Specification Details
Product Name Bipolar Prosthesis RG (Cemented)
Head Size 47mm
Fixation Type Cemented
Material Stainless Steel
Design Bipolar (dual-articulation)
Power Source Manual (surgical instrumentation)
Usage Environment Hospitals, orthopedic surgical departments

Common Uses for the Bipolar Prosthesis RG (Cemented)

Overall, orthopedic surgical teams use this prosthesis for several core applications:

Hip Fracture ManagementSince femoral neck and hip fractures often require joint replacement, this prosthesis supports surgical treatment of such cases.

Degenerative Joint ConditionsSimilarly, conditions affecting the hip joint’s natural function may call for bipolar prosthesis implantation.

Hip Arthroplasty ProceduresIn addition, hospitals performing hemiarthroplasty or related hip replacement surgeries use this component as part of the procedure.

Cemented Fixation CasesConsequently, surgeons selecting cemented fixation over cementless techniques, based on patient bone quality and surgical judgment, use this prosthesis accordingly.

Benefits of Using the Bipolar Prosthesis RG (Cemented)

This prosthesis gives orthopedic surgical teams a reliable component for hip joint reconstruction. Since the bipolar design allows movement at two articulating surfaces, it may help support smoother joint mechanics following surgery. Because the stainless steel construction offers durability, hospitals can rely on this component for long-term joint function needs. Consequently, orthopedic departments may find this prosthesis a practical addition to their surgical inventory for hip replacement cases.

Why Choose the Bipolar Prosthesis RG (Cemented) from Medical Outlet?

This prosthesis stands out for its precise 47mm sizing and dependable cemented fixation approach. As a component suited to hospital orthopedic departments, it supports surgical teams managing hip fracture and joint replacement cases. Moreover, its stainless steel build gives surgeons a durable option within the bipolar prosthesis category.

Ideal For

  • Orthopedic Surgical Departments
  • Hospitals Performing Hip Arthroplasty
  • Surgeons Managing Hip Fracture Cases
  • Cases Requiring Cemented Fixation

Frequently Asked Questions (FAQs)

1. What is the Bipolar Prosthesis RG (Cemented) used for?
It’s used in hip joint replacement surgery, particularly for cases involving hip fractures or degenerative joint conditions requiring bipolar hemiarthroplasty.

2. What does “cemented” mean in this context?
Because the implant uses bone cement to secure the prosthetic stem within the femoral canal, this fixation method provides immediate mechanical stability after implantation.

3. What size is this prosthesis?
This prosthesis comes in a 47mm head size, which supports precise anatomical fit during hip reconstruction.

4. What material is this prosthesis made from?
Specifically, it’s constructed from stainless steel, chosen for its durability under ongoing joint loading.

5. What does “bipolar” mean for this type of prosthesis?
Since the design allows movement at two articulating surfaces — between the stem and inner bearing, and between the outer shell and the natural socket — this may help distribute joint stress more evenly.

6. What does “manual power source” refer to?
This term refers to the manual surgical instrumentation used during implantation, not any powered mechanism within the prosthesis itself.

7. Who typically uses this prosthesis?
Orthopedic surgeons and hospital surgical departments use this prosthesis as part of hip joint replacement or hemiarthroplasty procedures.

8. Is this prosthesis suitable for all hip replacement cases?
Because the choice between cemented and cementless fixation depends on individual patient bone quality and surgical assessment, the treating orthopedic surgeon determines suitability on a case-by-case basis.

9. Does this implant require specific surgical instrumentation?
Yes, implantation requires appropriate surgical instrumentation and technique as determined by the operating surgeon and standard orthopedic protocols.

10. Where can hospitals get this prosthesis in Pakistan?
Medical Outlet supplies the Bipolar Prosthesis RG (Cemented) to hospitals and orthopedic surgical departments across Pakistan.

Conclusion

In summary, the Bipolar Prosthesis RG (Cemented) offers a 47mm stainless steel implant designed for cemented hip joint replacement procedures. Thanks to its bipolar design and durable construction, it supports orthopedic surgical teams managing hip fracture and joint reconstruction cases. Overall, this prosthesis stands as a component within Medical Outlet’s surgical implant offerings across Pakistan.

0 reviews for Manual Power Source Stainless Steel 47mm Joint Replacement Prosthesis – Bipolar Prosthesis RG (Cemented) in Pakistan

There are no reviews yet.

Be the first to review “Manual Power Source Stainless Steel 47mm Joint Replacement Prosthesis – Bipolar Prosthesis RG (Cemented) in Pakistan”

Your email address will not be published. Required fields are marked *